6000 Series Oscilloscopes
TDS6000B
DSO Series provides unprecedented performance along with a complete feature
set designed to address validation, debug, and compliance challenges of
next generation computer, datacom, and communications equipment. See how
Pinpoint™ trigger offers over 1,400 combinations to enable you to
find your problems faster.
Features at a Glance
• Bandwidths of 15 GHz (TDS6154C), 12 GHz (TDS6124C), 8 GHz (TDS6804B), and 6 GHz (TDS6604B)
• 3Risetimes to 19 ps 20-80% (28 ps 10-90%) on TDS6154C typical risetime, with channel-matched, user-selectable DSP
• 40 GS/s real-time sample rate on two channels (for C Model versions only), 20 GS/s real-time sample rate on all four channels with 500 fs/sample interpolated points
• Up to 64 Megasamples on two channels (for C Model versions only), up to 32 Megasamples record length on all four channels with MultiView Zoom™ function for quick navigation
• Pinpoint™ triggering provides highest performance and over
1400 triggering combinations
• MyScope® Custom Control Windows Enhance Productivity
• Serial data compliance and analysis up to 6.25 Gb/s
• OpenChoice® software with Windows XP OS delivers built-in
networking and analysis
• Technology specific software solutions provide built-in domain
expertise for serial data, jitter, ethernet, DVI, USB2.0, communications,
and power measurements
• System includes: high resolution XGA display, front panel CD-R/W,
front panel USB2.0 drive, and 1000BaseT network connection
• System includes: Dual processor system (2.8 GHz Pentium 4 and 583 MHz PowerPC),
high resolution XGA display, front panel CD-R/W, front panel USB2.0 port, and 1000BaseT network connection
Applications
• Signal Integrity, Jitter and Timing Analysis
• Validation, Debug and Characterization of Next Generation Digital Designs
• Debug of Computer, Datacom, Storage Area Network Equipment Designs and High-speed Backplanes
• High Energy Physical measurements and Data Acquisition
Uncompromised Acquisition
You won’t need to need to trade-off bandwidth, record length, and sample rate for your serial data measurement and analysis needs. The TDS6000C DSOs provides acquisition architecture with 40 GS/s maximum sample rate and 64 Megasamples record length on two channels (20 GS/s and 32 Megasamples on each of the four channels simultaneously), for the acquisition power you need. They provide the ultimate combination of bandwidth, sample rate, and record length for the fastest signals. The TDS6154C provides matched 15 GHz performance across any two channels using advanced, Tektronix-proprietary DSP enhancement, important for high speed channel-channel measurements. The user-selectable DSP filter on each channel provides magnitude and phase correction, plus extension of the analog bandwidth to 15 GHz for more accurate signal fidelity on high speed measurements — easily capturing the fifth harmonic of 3.0 GHz embedded clocks used in next generation 6.0 Gb/s serial data standards, and even the third harmonic of 5 GHz clocks being developed for future systems. The DSP filter on each channel can also be switched-off to take advantage of true 12 GHz analog bandwidth for applications needing the highest-available raw data capture.
Pinpoint™ Triggering
The
ability to trigger an oscilloscope on events of interest is paramount
in high speed debug and validation. Whether your trying to isolate a system
error or need to isolate a section of interest of a complex signal for
further analysis, Tektronix’ new Pinpoint trigger system provides the
solution. The Pinpoint trigger system uses Silicon Germanium (SiGe) technology
to provide trigger sensitivity of up to 9 GHz (TDS6000C models), and allows selection of all trigger types on both A and B trigger circuits. I t can capture glitches less
than 100 ps wide with 1 ps RMS trigger jitter typical (TDS6000C).
In the past, advanced
trigger types were offered on a single event (A Event). If a delayed trigger
(B Event) were used, it would be limited to edge triggering and not provide
any way to reset the trigger after the B-event occurred (or didn’t occur).
With Pinpoint triggering, the system provides the full suite of advance
trigger types on both A and B triggers. Reset triggering provides the
ability to reset the trigger circuit after a specified number of events
or time so that even events in the most complex signals can be captured.
Other oscilloscopes offer less than 20 trigger combinations, while Pinpoint
triggering offers over 1400 combinations all at full bandwidth.
Unparalleled Analysis
Waveform data analysis can take many forms. Whether it’s a simple math
expression, waveform mask testing, a pass/fail compliance test, or a custom
application that you develop. The TDS6000B Series offers the industry's
most comprehensive set of analysis and compliance tools.
 Embedded Analysis Tools
Embedded in the oscilloscope
user interface is a wide range of analysis tools including Cursors, Measurements,
Math Equation Editor, Serial Data Communications Mask Testing (with Opt.
SM), and Spectrum Analysis.
Technology Specific Software Solutions
Validation, debug,
and compliance testing often require automated test tools that quickly
analyze waveform data and provide the answers you need. The TDS6000B Series
provides complete “turn-key” solutions for the most demanding technologies.
Differential Probing with Performance to >12 GHz
Most high speed signals today are differential. The P7313 12.5 GHz Differential Probing System provides true differential connection to the device under test for a variety of
connection requirements: solder-in, hand held, and fixtured. Typical system performance with
the TDS6154C exceeds 12.5 GHz bandwidth. The P7313 offers the lowest loading, highest signal fidelity, and
lowest cost per connection in the industry. Versatile, inexpensive Tip-Clip™ adapters provide the
optimum solution for virtually any connection need.
The P7380SMA Differential Probing System provides a 50 O per side termination network with a termination voltage. The termination voltage can
be applied externally or through the TekConnect® interface from the TDS6000 probe menu, or not used at all. A gain switch
provides two different sensitivity settings of the probe and an Aux Out provides an inverted version of the signal for
driving other equipment. The P7380SMA probing system used with the TDS6000 oscilloscopes provides an ideal solution for validation and
compliance testing of high speed serial data links.
View/download full specifications
|
|