Oscilloscopes Buying GuideTektronix RangeProduct Naming ConventionsThe Tektronix product naming convention uses the first digit as the series in question, the second two digits indicate the bandwidth, and the last digit the number of channels. For example, the Tektronix TDS2024 oscilloscope. '2' - This scope is part of the 2000 series Compare SpecsDownload comparison sheets for both the value
series Digital Phosphor TechnologyOscilloscope GuideA beginners guide introducing essential oscilloscope concepts is available below. After reading the guide you should know how oscilloscopes work, know the differences between analog, digital storage and digital phosphor and digital sampling oscilloscopes, describe electrical waveform types, understand basic oscilloscope controls and know how to take simple measurements: Tektronix Guide to Oscilloscopes Isolated ChannnelsWe have a seperate section on scopes with isolated channels. This includes the THS700 and the TPS2000 - the worlds first 4-isolated-channel, full featured, battery powered oscilloscope. With an isolated oscilloscope input channels are electrically isolated from the oscilloscope’s chassis and from one another. This alslows waveform comparisons to be made with different reference points. Pico PC-Based Oscilloscope GuideIf you are interested in a PC based solution then the following guide is useful. The first step in choosing an oscilloscope is not to look at adverts or scope specifications, rather it is to invest some time
thinking about what you will use it for and where. Considerations might be: Analog vs DigitalThe focus of this article is on Digital Storage Oscilloscopes (DSOs) as they represent the majority of new oscilloscopes purchased today. Before describing what to look for in an digital oscilloscope, it is necessary to begin by at least touching on analog. Most electronics engineers will have used an analog scope at some time and will be familiar with its layout and operation. In fact, many people purchasing oscilloscopes today are replacing analog with digital. Although there are still some engineers who love the look-and-feel (let alone the warmth) of analog scopes, they have few, if any, features that cannot be surpassed by a DSO. If you are still tempted by an analog scope you will find your choice limited. Only a few manufacturers still make analog scopes; some of the models still on sale are based on rather old technology and often have very limited performance. Buying a second hand analog scope may initially seem like good economic sense but, before doing so, check for the availability
of spares, as high repair costs can make the purchase a false economy. There are other criteria that have added weight to the analogue vs digital debate. DSOs: Modern DSOs, with their PC connectivity, can also be fully integrated into Automatic Test Equipment (ATE) systems. In addition, the DSO is often used as the front-end of a high speed data acquisition system, making the cost per channel much more economically viable. BandwidthThe first feature to consider is bandwidth. This can be defined as the maximum frequency of signal that can pass through the front-end amplifiers. It therefore follows that the analogue bandwidth of your scope must be higher than the maximum frequency that you wish to measure (real time). Bandwidth alone is not enough to ensure that a DSO can accurately capture a high frequency signal. The goal of scope manufacturers is to achieve a specific type of frequency response with their designs. This response is known as the Maximally Flat Envelope Delay (MFED). A frequency response of this type delivers excellent pulse fidelity with minimum overshoot, undershoot and ringing. However, since a DSO is composed of amplifiers, attenuators, ADCs, interconnects, and relays, MFED response is a goal that can only be approached, and never met completely. It is worth noting that most scope manufacturers define the bandwidth as the frequency at which a sine wave input signal will be attenuated to 71% of its true amplitude (-3dB point). Or, to put it another way, they allow the displayed trace to be 29% in error of the input before calling it a day. Remember also that, if your input signal is not a pure sine wave, it will contain higher frequency harmonics. For example, a 20MHz pure square wave viewed on a 20MHz bandwidth scope will be displayed as an attenuated and distorted waveform. As a rule of thumb, try to purchase a scope with a bandwidth five times higher than the maximum frequency signal you wish to measure. Unfortunately, high bandwidth scopes are expensive, so you may have to compromise here. On some scopes, the quoted bandwidth is not available on all voltage ranges, so check the data sheet carefully. Sample RateWith analog scopes life was simple: you just selected the bandwidth that you required. For digital scopes, sampling rate and memory depth are equally important. For DSO's, the sampling rate is usually specified in mega samples per second (MS/s) or giga samples per second (GS/s). The Nyquist criterion states that the sampling rate must be at least twice the maximum frequency that you want to measure: for a spectrum analyser this may be true, but for a scope you require at least 5 samples to accurately reconstruct a waveform. Most scopes have two different sampling rates (modes) depending on the signal being measured: real time and equivalent time sampling (ETS) - often called repetitive sampling. However, ETS only works if the signal you are measuring is stable and repetitive, since this mode works by building up the waveform from successive acquisitions. For example the Pico Technology 12-bit ADC-212/100 will sample at 100MS/s real-time or, for repetitive waveforms, at 5GS/s. 5GS/s sounds great, but remember that if the signal is a transient or changing (say a video waveform) then ETS will not work and you will have to rely on the real time (single shot) bandwidth, which is typically much lower. Some scopes have different sampling rates, depending on the number of channels in use. Typically, the sampling rate in single channel mode is twice that in dual channel mode: once again, check the specifications. Memory DepthMemory depth is perhaps the least understood aspect of a DSO which is a shame because it is one of the most important. DSOs store captured samples in a buffer memory, so, for a given sampling rate, the size of the buffer memory determines how long it can capture a signal for before the memory is full. The relationship between sampling rate and memory depth is important; a scope with a high sampling rate but small memory will only be able to use its full sampling rate on the top few timebases. Real World ExampleTo make sense of the relationship between bandwidth, sampling rate and memory depth, it makes sense to consider a real world
example. Consider trying to capture one frame of USB (1.1) data. A frame of data lasts 1ms and has serial data transmitted at 12MBPS.
To simplify our analysis, we can assume that we have to capture a 12MHz square wave for 1ms. Resolution and AccuracyIn digital electronics, a signal change of 1% is usually no problem, but in audio electronics, 0.1% distortion or noise can be a disaster. Most modern DSOs are optimised for use with fast digital signals and only offer 8 bit resolution (8 bit ADC), so can detect at best a 0.4% signal change. With 8 bits, the voltage range is divided up into 256 vertical steps (2^8 = 256). With a +/-1V range selected, this corresponds to around 8mV per step. This may be adequate for viewing digital signals but leave something to be desired for viewing analog signals, especially when using the spectrum analyser function (if it has one). For applications such as audio, noise, vibration and monitoring sensors (temperature, current, pressure) an 8 bit oscilloscope is often not suitable and you should consider 12 or 16 bit alternatives. As for a DSO's accuracy, it is not usually regarded as too important. You can make measurements within a few percent (most 8 bit DSO's quote 3% to 5% DC accuracy) but for more accurate measurements you should reach for a multimeter. With a higher resolution oscilloscope, more accurate measurements are possible (1% or better) so - no need for the meter. Oscilloscopes with both a high resolution (12 bits or more) and a high DC accuracy are sometimes referred to as precision oscilloscopes. Triggering CapabilitiesA scope's trigger function synchronises the horizontal sweep at the correct point of its signal: this is essential for clear signal characterisation. Trigger controls allow you to stabilise repetitive waveforms and capture single-shot waveforms. Depending on the type of signals being investigated, it is worth looking at the trigger options offered by a manufacturer. All digital scopes offer the same basic trigger options (source, level, slope, pre/post trigger) but differ in the more advanced trigger functions. Whether or not the more advanced trigger functions will be useful again depends on the signals being measured. Pulse triggers are useful for digital signals, and an automatic save to disk/memory option can be a great help when tracking down intermittent faults. Input Ranges & ProbesA typical scope will offer selectable full scale input ranges from +-50mV to +-50V. As higher voltages can be measured using 10:1 and 100:1 attenuating oscilloscope probes, the important thing here is to check that the scope has a small enough voltage range for the signals that you want to measure. If you regularly measure small signals (less than 50mV), consider buying a scope with a 12 or 16 bit resolution. A 16 bit scope has 256 times the vertical resolution of an 8 bit schop[e, making it possible to 'zoom in' on millivolt and microvolt level signals. Check that the scope probes you plan to use match - or better - the bandwidth of the scope. Some manufacturers make cost savings by supplying sub-standard probes with the scope and only supply the higher bandwidth probes, which are needed to get the best from the scope, as optional extras. Most scope probes can be switched between 1:1 and 10:1 attenuation. Wherever possible, use the 10:1 setting as this minimises loading on the circuit under test and increases the overload protection should you accidentally connect to a high voltage. For very high speed signals (>200MHz), passive probes begin to run into problems caused by the capacitance of the cable going back to the scope. This can be solved by investing in an active FET probe which places a buffer amplifier in the probe tip. For measuring high voltages, for example >100V, mains and 3 phase voltages, the safest option is to use a differential isolating oscilloscope probe. Form FactorDSOs broadly fall into three categories: traditional bench-top, hand-held, and PC-based. A purpose built benchtop digital scope will usually have the highest performance, and that will be reflected in the cost. Features such as FFT spectrum analysis, PC interfaces, disk drives and printers all tend to be expensive optional extras. Hand-held oscilloscopes have obvious advantages for an engineer on the move, but beware of poor displays (difficult to read in sunlight) and short battery life. For a given performance level they also tend to be the most expensive option. PC based oscilloscopes are growing in popularity as they offer a considerable cost saving over their benchtop equivalents. The reason for the cost saving is obvious; by using the mass produced PC already sitting on your desk, you end up with a large colour display, fast processor, disk drives and keyboard effectively for free. The ability to export data to wordprocessors and spreadsheets with a couple of mouse clicks is also a big advantage. PC based scopes come in two varieties: external and internal. Internal PC based scopes usually come in PCI format plug in cards. In theory, these should be the lowest cost option but this does not always prove to be true. The main disadvantage of PC cards is noise - the inside of a PC can be a very noisy electrical environment and some cards do suffer. Another issue is portability; oscilloscopes based on PC cards are tied to being used with one desktop PC. External PC based oscilloscopes take the form of a small box that connects to the PC via either the USB or the parallel port. By keeping all the analog electronics outside the PC, the noise problem is avoided. A second advantage of external PC-based scopes is portability - they can be used with either desktop or laptop PCs. Summing UpLike the dinosaur, the analog scope has really had its day. The cost and performance arguments have made sure that the DSO
is here to stay. It only remains to decide which type to buy. When choosing between different scopes, check the following: Classroom ResourcesIMEX have some classroom resources in our support section which may be useful for laboratory teaching and classroom activities. The Operator Training Kit provides education about the features, uses
and basic operation of an oscilloscope through its extensive instructions and step-by-step lab
exercises. The kit includes a self-paced, CD-ROM-based manual and signal source board.
An optional hard copy manual is available and can be ordered separately. The kit is designed specifically
for the Tektronix TDS200, TDS1000, TDS2000, TDS3000, and TDS3000B Series instruments. This is a fantastic tool
for universities and schools. The training kit includes: |
|
©2008 IMEX Systems Limited - All rights reserved |