1604
1604 - 40,000 Count LED Bench Multimeter
- 40,000 counts, auto/manual ranging
- Accuracy and resolution, 0.08%, 10µV, 10mW
- Large and bright LED display (14mm/0.56")
- True RMS ac functions, wide ac bandwidth
- Frequency measurement
- Relative, T-Hold and Min-Max functions included
- Isolated RS232 interface standard
| DISPLAY and RANGE CONTROL 0.56” (14mm) LED display. Annunciators for all ranges, functions and 'smart' modes. Scale Length 4¾ digits (± 40,000 counts) except ac ranges ( 4,000 counts). Reading rate 2.5 per second. Each measurement function can use automatic or up/down manual ranging. RS-232 INTERFACE Opto-isolated bi-directional RS-232 interface. 9600 baud. GENERAL Power: 230V or 115V AC nominal 50/60Hz, adjustable internally; operating range ±14% of nominal; 3VA max.; Installation category II Size: 260(W) x 88(H) x 235(D)mm, excl. handle/feet. Weight: 2.0kg (4.4lb) Operating Range: + 5°C to 40°C, 20-80% RH. Storage Range: - 40°C to 70°C Safety: Complies with EN61010-1. EMC: Complies with EN55081-1 and EN50082-1. |
All accuracies apply for 1 year, 19oC to 25oC. Temperature coefficient outside these limits is <0.1 x quoted range accuracy per oC.
DC VOLTAGE
|
Range
|
Accuracy
|
Resolution
|
Notes
|
|
400mV
|
0.08% ± 4 dig.
|
10µV
|
Max. Input 265V DC/AC rms
|
|
4V
|
0.08% ± 4 dig.
|
100µV
|
Input impedance 10MW nominal Max. input 1kV DC or AC pkNMR: >60dB @ 50/60HzCMR: >90dB @ DC/50Hz/60Hz
|
|
40V
|
0.08% ± 4 dig.
|
1mV
|
|
|
400V
|
0.08% ± 4 dig.
|
10mV
|
|
|
1000V
|
0.09% 4 dig.
|
100mV
|
AC VOLTAGE (True RMS, 4000 count scale length)
|
Range
|
Accuracy
|
Resolution
|
||
|
|
45Hz - 400Hz
|
400Hz - 5kHz
|
5kHz - 20kHz
|
|
|
400mV
|
0.5% ± 4 dig.
|
1% ± 4 dig.
|
3% ± 4 dig.
|
100µV
|
|
4V
|
2% ± 4 dig.
|
5% ± 4 dig.
|
1mV
|
|
|
40V
|
10mV
|
|||
|
400V
|
3% ± 4 dig.
|
100mV
|
||
|
750V
|
1% ± 4 dig.
|
|
1V
|
|
Accuracies apply for readings between 10% and 100% of full scale. Additional error at crest factor = 3 is typically 1%. Input impedance = 10MOhms nominal. Max. input = 750V rms, 1kV pk. (265V rms on 400mV range). 1kOhm unbalanced CMR = >60dB at DC or 50Hz (60Hz rejection available as factory option).
RESISTANCE
|
Range
|
Accuracy
|
Resolution
|
Notes
|
|
400W
|
0.15% ± 6 dig.*
|
10mW
|
* 400Ohm specification applies after null Max. input 265V DC or AC rms on any range
.Max. open circuit voltage 4V 40MOhm accuracy applies up to 20M thereafter add 1% |
|
4kW
|
0.1% ± 4 dig.
|
100mW
|
|
|
40kW
|
0.1% ± 4 dig.
|
1W
|
|
|
400kW
|
0.15% ± 4 dig.
|
10W
|
|
|
4MW
|
0.3% ± 6 dig.
|
100W
|
|
|
40MW
|
1.0% ± 10 dig.
|
1kW
|
DC CURRENT
|
Range
|
Accuracy
|
Resolution
|
Notes
|
|
4mA
|
0.1% ± 4 dig.
|
0.1µA
|
Max. input 1A (Fused)
Voltage burden <500mV |
|
400mA
|
0.1% ± 4 dig.
|
10µA
|
|
|
10A (up to 1A)
|
0.3% ± 4 dig.
|
1mA
|
Max. input 10A (Fused)
Voltage burden <500mV |
|
10A (up to 5A)
|
1.0% ± 4 dig.
|
1mA
|
|
|
10A (up to 10A)
|
3.0% ± 10 dig.
|
1mA
|
AC CURRENT (True RMS, 4000 count scale length)
|
Range
|
Accuracy
|
Resolution
|
Notes
|
|
1mA
|
0.5% ± 4 dig.
|
1µA
|
Max. input 1A (Fused)
Voltage burden <500mV |
|
100mA
|
0.5% ± 4 dig.
|
100µA
|
|
|
10A (up to 1A)
|
0.8% ± 4 dig.
|
10mA
|
Max. input 10A (Fused)
Voltage burden <500mV |
|
10A (up to 5A)
|
1.5% ± 4 dig.
|
10mA
|
|
|
10A (up to 10A)
|
3.0% ± 4 dig.
|
10mA
|
Accuracies apply over 45Hz to 10kHz for readings between 10% and 100% of range. Additional error at crest factor = 3 is typically 1%.
| Attachment | Size |
|---|---|
| prec-1604-2p.pdf | 222.23 KB |